Section 7.18.530. Personnel monitoring control.  


Latest version.
  • 	(a)   A registrant of an x-ray machine used in industrial radiography may not permit an individual to act as a radiographer or as a radiographer's assistant unless, at all times during radiographic operations, the individual wears a radiation detecting badge and either a pocket dosimeter, chamber, or other direct reading device.  The direct reading device must be capable of measuring doses from zero to at least 200 milliroentgens.  A badge may be assigned to and worn by only one individual.  
    	(b)  The registrant shall assure that direct reading devices are read and doses recorded daily and that a radiation detecting badge is processed immediately if a pocket dosimeter, chamber, or direct reading device is discharged beyond its range.  
    	(c)  The radiation detecting badge reports received from the badge processor and records of pocket dosimeter, chamber, or direct reading device readings shall be retained indefinitely, or until the registrant terminates operation and transfers personnel records to the department.  
    